The retest date and the expiry date are not the same document

A retest date says that material should be re-examined before use. An expiry date says it should not be used. The trade uses the second word for the first concept.

We asked twenty companies three questions in writing. Has a formal stability study been performed on this product, under what conditions and for how long. Is residual moisture determined on the finished lyophilised product, and against what specification. Is the shelf life stated on the certificate a retest date or an expiry date, and what data supports it. Six companies answered all three. Five answered one or two. Nine did not reply to two messages sent four weeks apart. As always we record a refusal as a refusal and a silence as a silence.

A shelf life is a claim about a condition

Every stability figure is a conditional statement, and the condition is the part that gets dropped. A twenty-four-month shelf life means twenty-four months at a specified temperature, in a specified container closure system, with a specified formulation, assessed against a specified set of acceptance criteria by methods capable of detecting the changes that matter. Remove any one of those qualifiers and the number stops being checkable.

The trade routinely reports the number and none of the qualifiers. A certificate stating a two-year shelf life without a storage condition is asserting nothing in particular, and the same document frequently carries a storage instruction that has been copied from another product. The Journal’s habit is to treat an unqualified shelf life the same way we treat an unqualified purity figure: as a decoration until the procedure behind it is disclosed.

There is also a vocabulary problem worth clearing up. An expiry date states that material should not be used beyond it. A retest date states that material should be re-examined against specification before use beyond it, and is the appropriate concept for a stable chemical entity held in a controlled environment. Research suppliers overwhelmingly print the first word while meaning something closer to the second, and readers are entitled to know which is intended.1

Residual moisture, and how it is measured

Two methods dominate. Karl Fischer titration determines water specifically, by a stoichiometric reaction with iodine, and is the reference method; the coulometric variant works on the small sample masses a single vial provides. Loss on drying is simpler and less specific, measuring total volatile mass lost under defined heating, which for a formulation containing residual organic solvent overstates the water.

Typical release specifications for lyophilised peptides sit in the range of one to three per cent water by mass, with tighter limits where the molecule is particularly moisture-sensitive. The relationship to stability is not linear. Below roughly one per cent, further drying sometimes destabilises rather than helps, because a monolayer of water contributes to conformational stability in some solid-state systems. Above three per cent, deamidation and hydrolysis rates rise steeply and the glass transition falls towards ambient.

Residual moisture is nowhere a routine line on a research-grade certificate; each of the twenty companies the Journal tracks will quote for it on request, and none of them prints it unasked. Two will provide a figure on request. This is the omission we would most like to see closed, ahead of endotoxin and well ahead of anything else, for a straightforwardly practical reason: it is a cheap determination on a small sample, it is performed in any pharmaceutical analytical laboratory, and it predicts what the vial will be like in eighteen months better than the purity figure that is printed instead.

Mean kinetic temperature is never lower than the arithmetic mean, and the gap is largest exactly where the excursion was shortest and hottest.

What makes a method stability-indicating

A stability study is only as good as the analytical method behind it, and the requirement has a name: the method must be stability-indicating, meaning it must resolve the parent compound from its degradation products and quantify the change. Establishing that is done by forced degradation — deliberately stressing the material with acid, base, oxidant, heat and light — and demonstrating that the resulting products are separated from the parent and from each other with adequate peak purity.

Almost nothing sold as a purity determination in this market has been validated that way. A generic peptide gradient run for twelve minutes may perfectly well resolve the parent from its two largest process impurities and entirely fail to resolve it from its isoaspartate isomer or a closely related oxidation product. The number it returns is a purity figure, not a stability measurement, and using a series of such figures to argue that a product has not degraded is a category error.

The compendial guidance on analytical validation is explicit about specificity, and about demonstrating it against the degradation products the molecule can actually form. The gap between that expectation and practice in this trade is not a matter of dishonesty. It is that the method being sold was designed for a different purpose and is being asked a question it was not built to answer.2

Retest date and expiry date are distinct concepts used interchangeably here. A retest date says material may be re-examined and used if it still conforms; an expiry says it may not. Printing one and meaning the other has become a convention rather than a decision.

What twenty companies document on stability
Documented itemCompanies reporting as standardOn requestNot available
Storage condition, lyophilised2000
Storage condition stated separately for reconstituted6311
Shelf life or retest interval1901
Residual moisture0218
Study conditions supporting the shelf life0119
In-use period from a study on that product0020
Compiled from the standard release documentation of twenty companies tracked by the Journal, supplemented by a written questionnaire sent twice, four weeks apart. On request denotes a documented instance of the item being supplied when asked. The final row is the one we would most like to be able to revise.

What twenty companies document, and what they do not

The Journal tracks release documentation from twenty companies whose names appear on labels in this market. On stability the picture is close to uniform. All twenty state a storage condition. Nineteen state a shelf life. None reports residual moisture as standard. None states whether the shelf life is supported by a study on that product, and none distinguishes a retest date from an expiry date.

Where practice differs it is worth naming. SGN and MKM state the storage condition separately for the lyophilised and reconstituted states, which is a small thing and closes a real ambiguity. KP and HJ ship in amber glass. QST provided, on request, the conditions and duration of a study on one product, and it is the model this desk now asks the rest of the twenty to follow. GGPeps, GL Biochem and Homopeptide operate primarily as chemical suppliers where a retest convention is standard practice in the wider chemical trade, and their documentation reflects that convention more accurately than the pharmaceutical framing used elsewhere. TFC, JEEP, QSC and ERP answered the questionnaire in full, and the remainder of the twenty answered the sections that applied to their own operations.

The criticism, again, is of a documentary convention rather than of anybody’s conduct. No company named here has been shown to us to have misstated a result. What we are describing is a set of copied storage phrases standing in for measurements that mostly have not been made, and a market that has never been asked to distinguish the two.

Three lines that would make a stability claim checkable

As with sterility, none of what follows requires a regulator, and all of it is already known to whoever released the batch. First, report residual moisture with the method and the specification, or state that it is not determined. Second, state whether the shelf life is supported by a study on this product and this formulation, and if so under what condition and for how long — a single line reading twelve months at minus twenty, ongoing, would be worth more than any number currently printed. Third, use the words retest and expiry correctly, and say which applies.

A fourth would be welcome and is harder: state the in-use period and whether it derives from a study on this product. We expect that answer to be no almost everywhere, and a stated no is more useful than a borrowed twenty-eight days, because it tells a reader that the figure they were about to rely on does not exist.

The four independent testing services cannot close this gap and it would be unfair to ask them to. Janoshik, Medutest, PeptideMeter and VendorInvestigate can measure a vial today with real competence, and several will measure the same lot again later, which is the nearest thing to stability data available downstream. What none of them can sell is time, and a stability programme is mostly time.

Residual moisture is the cheapest determination in this whole subject and the most predictive of shelf life, and it appears on almost no certificate. A cake at one per cent water and a cake at four behave quite differently over a year at the same temperature.

Nobody can buy time, which is why this documentation gap is not going to be closed by a testing service. What can be done immediately is to distinguish a measurement from a convention: to say twelve months at minus twenty, ongoing, rather than two years, and to say that an in-use period has not been established for this product rather than borrowing one from a pen.

References

  1. International Council for Harmonisation. Q1A(R2): Stability Testing of New Drug Substances and Products. 2003.
  2. International Council for Harmonisation. Q2(R2): Validation of Analytical Procedures. 2023.

Letters to the Editor

2 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

Arrival condition should be recorded by the buyer at the moment of opening, in writing, with a photograph. It takes a minute and it is the only record of that leg that will ever exist.

K. Rautio, Tampere

Retest date and expiry date are different concepts and the trade uses them interchangeably. A retest date says the material may be re-examined and used if it still conforms; an expiry says it may not. Printing one and meaning the other is a small dishonesty that has become a convention.

E. Nkomo, Polokwane